The necessity of fire inspection cabinets

February 10th, 2022
147 times
Fire pump automatic inspection control cabinet, also known as fire intelligent digital inspection device. This device can prevent faults such as corrosion, humidity, and abnormal pump movement of the fire pump, and indeed achieve the goal of thousands of days. In the construction of Fire protection engineering, fire inspection cabinet plays an important role in ensuring fire safety management and realizing safe operation of * *. So, what is the function of the fire inspection cabinet? 1、 Intelligent fire inspection is necessary. Fire water supply equipment is an important component of the fire protection system, whether it is a fire linkage alarm system or various automatic fire control equipment to judge disasters until they alarm, and ultimately start the fire pump and fire control cabinet as one of the fundamental purposes. There is a common problem with various fire water supply equipment nowadays: in building fires, a considerable number of fire pumps cannot start after receiving a start signal, delaying fire opportunities, causing huge losses to national property and people's safety. The main reason is that the fire pump does not start, and most enterprises purchase fire pumps that are not made of stainless steel material. Over time, in the humid environment of the pump room, the internal pump shaft, impeller, and The phenomenon of shaft sleeve rust death. Given the above situation, it is necessary to conduct regular inspections of the fire pump and control cabinet to maintain the mechanical performance of the fire pump and the performance of the electrical control cabinet, always in good condition. This inspection method can fundamentally solve the serious consequences of rust on the fire pump. To address the implementation of fire water supply equipment and the implementation of fire water supply equipment. According to the Fire Safety Industry Standard GA30.2 "Performance Requirements and Test Methods for Fixed Fire Water Supply Equipment" of the Ministry of Public Security, in order to prevent faults such as corrosion, moisture, and abnormal pump movement of fire water pumps, automatic inspection devices must be installed on fire water pumps. The inspection is a low-frequency inspection, with a motor speed of 300 rpm. The water system is not pressurized and has no starting current, greatly extending the service life of the equipment. This inspection method has high safety, low current, and low power consumption, and is a standard inspection method that meets the requirements of the Ministry of Public Security industry.

label

Previous article: 2022-02-10
Next article: 2022-02-10
  • Website homepage
  • Consultation hotline
  • Back to top